Hurricane Wind Power 24 Volt Permanent Magnet Alternator PMA Delco
$350.0 Buy It Now or Best Offer
free,30-Day Returns
Seller Store
() %,
Location: Roanoke, Virginia, United States
Ships to: US,
Item: 266111886120
Condition:New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is … Read moreabout the conditionNew: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller’s listing for full details. See all condition definitionsopens in a new window or tab
Hurricane:Hurricane
Type:Permanent Magnetic Alternators
Current Type:3 Phase AC (Converts to DC through a rectifier)
System Configuration:Off-Grid
Power Source:Wind
Color:Red
24VPMA:24VPMA
MPN:24VPMA
Country/Region of Manufacture:United States
Application:Agriculture/Farming, Aquaculture, Back-up Power, Commercial, Home/Garden
UPC:Does not apply
eBay Hurricane Wind Power 24 Volt Permanent Magnet Alternator PMA Delco 3 Phase (converts to DC through a rectifier) Yes you have arrived at the listing for the PMA more DIY builder choose year in and out and here is why. No sensationalism , hype or desperation. It is very true that sometime a good company is what it is not. We will take a moment to address the pathetic attempts of a competitor on this site to discredit our product. We have shown out product running cool under load. We have shown the build videos and we have shown the internal components of these machine we build. So consider the following. If you take a new from the auto parts store alternator alternator you will find that is has 14 poles with equal magnetism You will find a claw shaped pole allowing for transitioning to from pole to pole without cogging as we have always advertised You will not find a small rectangular pole / rotor segment You will not find unequal magnetism based on the use of an uneven field as is the case on the cut rate 7 magnet version of this product Finally if the coating will cause our product to overheat which it does not bad news for all you guys with chrome alternators on your hot rods We build the quality products to be defined by us and our legitimate customers…..not jealous competitors There you have it no over sensationalism or hype just good product from the American working man. See below our products in action My apologies for the lengthiness of this description. My review of the generator sales has led me to the conclusion that most of the current market has to offer is “sales pitch”. It is my intent to simply show here what we offer, our capabilities, and the methodology behind our designs. While some information is proprietary we feel the basic information should be available to the discerning customer whom is attempting to decipher fact , from fiction, weird science and smoke and mirrors. Why buy from Hurricane? This is probably the most frequent questions anyone in business is asked. We have outlined the pertinent information in bulleted segments. We explain the methodology last. If you are new to wind power you should read the section and watch the videos in the embedded playlist if you are interested in the science behind the products . I recognized that understanding the basics is important. Many customers are interested but other just want the shortened version with the specs and pertinent information. As intelligent consumers we are aware that you know bolting an imported generator to a body does not mean it is made and manufactured in the USA and anyone can show a meter on a video. Simply ask: Where is the PMA made? Wind generators are for the most part rated at the top end on power curves at wattage values. Many companies simply ignoring the 24.9 MPH power rating set by the Nation Research Energy Laboratory. The only thing that is important when selecting a permanent magnet alternator is which one will produce the most power over time. Since our beginnings we have held true to this principle which essentially holds that the majority wind generators available do not reach cut in speeds or produce so much as a trickle charge in low wind. Hurricane Low Wind PMA’s have the ability to reach cut in i.e produce power when other products are simply big pinwheels in your yard. Results measured using 5 storm rotation Gen II blades For even more powerful permanent magnet alternators check out our NEO CORE Twin output (TM) and Air Boss Axial Flux APMA’s The vast majority of the country is in a low wind zone lighter shades of blue or white…. if this is your area you should consider this PMA. If you are blessed with higher wind speed average consider our Mark II or III with heavier windings. Our PMA’s will reach cut in speeds and produce power in and low as 6 mph wind and we can demonstrate this. The below video features our dual PMA wired in series not the single PMA therefore the output would be roughly half or twice the RPM to achieve the RPM you are viewing in the video In my experience most customers do not care about an open voltage times shorted amps chart value calculated in 70 mile per hour winds. For these reasons we offer the open voltage multiplied by shortage amp style chart, The wattage output VS wind speed at battery bank environment, and monthly power output in KW hours per month to provide a comprehensive illustration of the capabilities of our products. Many power curves and charts are fiction i.e made, Mythical and comical. Open voltage multiplied by shorted amps do not give the customer a realistic perception of how much power a product will output. The two conditions are separate, open voltage measurements are not taken under a load while shorted amp readings are. This information is useful for some purposes but virtually useless for others. If you are interested we have charted the Cat 4 Mark IPMA in that format as well. Hurricane manufactures its own PMA’s no vendor is used, it is not imported, and is designed, manufactured and assembled in Roanoke Virginia USA. Since we make stock and assemble the product we have control over the warranty process. All products whether they are built by myself, a third party vendor, or simply imported will have issues. This is the way of the world and the is simply no way around it. People, nor material goods are free of imperfection. The issue becomes how a company deals with and customer service issues which arise. We are willing to go the extra mile. We will meet or exceed anyone’s warranty in the business. We have the parts in stock and if something goes wrong with you product we are not faced with the decision to take the “hit” and throw the product in the dumpster. Logically speaking, if we can build it we can repair it. Dual PMA shown performing under water Power output is limited to the power input of the old worn out drill but you get the point. The ability of to cool with an open design is very important due to the fact closed sealed PMA’s will lose power from the buildup of heat and eventually fail due to the stator inability to dissipate heat burning up windings. It is really a point of common sense. If you were in a hot metal box would you rather have it sealed with a cooling fin attached to the outside of your box or have a window open? The following is written with the intent of addressing wind applications but many of the principles apply to electromagnetic – mechanical transfer of energy in general. I apologize in advance for the length of the explanation but in the interest in the health of my jaw joint and phone bill, I will attempt here to lay out the basics as many of my new to the field. My customers want information and facts not puffery exaggerated, claims and “fantastic assertions”. How a Wind Generator works The science is what it is and we will tell you exactly why you should buy from Hurricane. The majority of what you have read while shopping for a wind generator PMA is fiction as I have eluded previously. We have inserted the following playlist so you may see the science behind the products if you are new to the field. Kinetic Energy transferred from the wind striking a surface, typically a set of blades is transferred to a generator. In the vast majority of all designs a magnetic rotor rotates around a stator a set of stationary coils, or the stator rotates around a stationary rotor. The force measured in torque eg. Ft/lbs, Newtons, Joules ect. that is transferred to the generator is changed in form from mechanical energy to electrical. Power input from a source has nothing to do with the generator or permanent magnet alternator but ultimately dictates the maximum power than may be output by a generator. This is why wattage rating without understanding input torque needed leads many to disappointment. Fast forward about 3 minutes in for the significant of the illustration The law of conservation of energy applies “ energy can neither be created nor destroyed but change form eg kinetic to mechanic, mechanical to electrical” ect. Simply stated it takes power to make power. To achieve maximum power from a wind generator the two elements which are of the essential are the amount of power or torque input from a source or blades set, and the efficiency of the generator. The circumference of the rotor area, number of blades are some of the variables which determine torque produced from a given rotor/blade set. The input torque eg. Maximum mechanical energy input is relative to the amount of electrical energy that can be extracted from generator. These same principle of torque input apply whether we are speaking of a wind generator, hydro, gas, diesel or any other power source which drive a permanent magnet alternator. In other words it takes power to make power Myth… the claw or zig zag design in a permanent magnet alternator is inferior? About Rotors Why the claw shape is superior…. The rotor has 7 poles sets distributed as “claws” around it’s circumference. One set of claws is thus a “north” pole and the other set is a “south” poles. The epoxy coated N 45 neo core magnet In Hurricane Rotors deeply saturates the stator. The iron originally used in the pole claw has been replaced utilizing higher efficiency shapes and forged steel a used in Hurricane permanent magnet alternators. The magnetic flux lines within the rotor are largely constrained to flow from one pole to the other through the claw structures at each end trapezoidal claw, folding around the internal magnetic structure and passing between the claws through a zig-zag shaped circumferential air gap. There is no reverse flux flow through the rotor shaft itself. The rotor shaft is magnetically entrained and acts as yet another part of the rotor Magnetic rotor. The shape of the zig-zag gap between the claw pieces, being air and much less permeable than the forged steel and directs the magnetic flux into a similar zig-zag shape. So as the rotor rotates there will be a position where this gap exactly bisects a stator segment and both the “north” and the “south” claws on either side of the gap will have an equal magnetic influence on it. As it continues to rotate more and more of the “north” or “south” claw will come adjacent to this particular stator coil, thus transferring the particular magnetic field polarity into it. This zig-zag “claw” design therefore prevents abrupt magnetic transitions from taking place in the stator segments as the rotor is turned. preventing abrupt transitions this elegant design thus largely eliminates any tendency to have a location, or a series of locations, where the magnetic path is more permeable and thus more attractive than adjacent locations. It is these variations in permeability around the circumference that are the cause of magnetic “cogging” in slotted magnet rotor designs. Of three companies rotor we examine which use this design two of three used magnet to wide for the field which is highly inefficient causing huge losses, heat buildup, e.g. eddy current resistive effects. In other words opposing poles entering the same field essentially fight against each other We have examined multiple “plate and grove designs” and I as well as many customers have found that some of the companies offering this type of design build PMA which have a terrible cogging effect and provide virtually no low end power . Faraday- Lenz Law Systems do not like change! The things that you should be concerned with when buying a generator for maximum efficiency are as follows. 1. ROTOR design and strength……this is simple as strong as possible designed in a manner in which the shaft is not difficult to turn and is designed in a manner to promote cogging. Also there are poor designs on the market I have examine that has poles to wide for the fields thus making the PMA terribly inefficient. 2. AIR GAP between the rotor and stator must be exact. This cannot be done be hand and should be done with precision to the 1000th of an inch to maximize efficiency 3. STATORS should be wound with a gauge of wire and winding connection that is appropriate for the particular application. E.g. high wind, wind. Battery bank voltage environment e.g. 12, 24, or 48 volt or the set point for the grid tie you are using. We use 400 degree wire in out stators which will withstand the test of time and extreme conditions. There is nothing magical about a hand wound stator other that the manufacturer could not afford to have enough wound to his specifications and made per the requirement he desired. Moreover by having the buying power to have our product wound professionally the wind is tighter allowing more copper to be wound into areas withing the stator which have deep flux saturation. 4. CRAFTSMANSHIP all connections must be made professionally, products such as lock tite used new parts forged with precision, A PMA is only as good as the person building it. If something does not fot precisely it is not good. Quality Control and balance of the rotating assembly not only effect performance they effect the longevity of a product. An out of balance product will wear the air gap between rotor and stator and guarantee a short bearing live. 5. VALUE We pledge you will not find a better product for the money period. Hurricane Learning LAB: if you are interested in the science behind the products here it is. No pitch nothing fancy it is what it is. Finally I do not consider myself the ultimate authority on Physics if you have a PHD in your pocket and have feedback we would love to hear from you. If your permanent magnet alternator manufacturer does not understand the principles contained within this playlist, they will be inept whether their task be manufacturing or importing. Perhaps it’s time to consider a Hurricane. Hurricane Wind Power Build News Magazine Best Off Grid 2016 Product Supplier Renewable Energy UP TO -50% DISCOUNTS TOP BRANDS Payment Shipping Returns Payment Shipping Returns We accept payment by any of the following methods: PayPal Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner! We offer Fast shipping on all orders! Your order will be dispatched within 1-3 working day of receiving payment (Monday-Friday) and you should expect to receive it one or two days after dispatch (for orders sent RM 1st Class). In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement. If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not. You can return a product for up to 14 days from the date you purchased it. Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt. See our other items Thank you for visiting our Ebay store! Click here to see description Low Wind Generator Permanent Magnet Alternator – Hurricane Cat IV-I Platinum PMA Yes you have arrived at the auction for the PMA more DIY builder choose year in and out and here is why. No sensationalism , hype or desperation. It is very true that sometime a good company is what it is not. We will take a moment to address the pathetic attempts of a competitor on this site to discredit our product. We have shown out product running cool under load. We have shown the build videos and we have shown the internal components of these machine we build. So consider the following. If you take a new from the auto parts store alternator alternator you will find that is has 14 poles with equal magnetism You will find a claw shaped pole allowing for transitioning to from pole to pole without cogging as we have always advertised You will not find a small rectangular pole / rotor segment You will not find unequal magnetism based on the use of an uneven field as is the case on the cut rate 7 magnet version of this product Finally if the coating will cause our product to overheat which it does not bad news for all you guys with chrome alternators on your hot rods We build the quality products to be defined by us and our legitimate customers…..not jealous competitors There you have it no over sensationalism or hype just good product from the American working man. See below our products in action My apologies for the lengthiness of this description. My review of the generator sales has led me to the conclusion that most of the current market has to offer is “sales pitch”. It is my intent to simply show here what we offer, our capabilities, and the methodology behind our designs. While some information is proprietary we feel the basic information should be available to the discerning customer whom is attempting to decipher fact , from fiction, weird science and smoke and mirrors. Why buy from Hurricane? This is probably the most frequent questions anyone in business is asked. We have outlined the pertinent information in bulleted segments. We explain the methodology last. If you are new to wind power you should read the section and watch the videos in the embedded playlist if you are interested in the science behind the products . I recognized that understanding the basics is important. Many customers are interested but other just want the shortened version with the specs and pertinent information. As intelligent consumers we are aware that you know bolting an imported generator to a body does not mean it is made and manufactured in the USA and anyone can show a meter on a video. Simply ask: Where is the PMA made? Wind generators are for the most part rated at the top end on power curves at wattage values. Many companies simply ignoring the 24.9 MPH power rating set by the Nation Research Energy Laboratory. The only thing that is important when selecting a permanent magnet alternator is which one will produce the most power over time. Since our beginnings we have held true to this principle which essentially holds that the majority wind generators available do not reach cut in speeds or produce so much as a trickle charge in low wind. Hurricane Low Wind PMA’s have the ability to reach cut in i.e produce power when other products are simply big pinwheels in your yard. Results measured using 5 storm rotation Gen II blades For even more powerful permanent magnet alternators check out our NEO CORE Twin output (TM) and Air Boss Axial Flux APMA’s The vast majority of the country is in a low wind zone lighter shades of blue or white…. if this is your area you should consider this PMA. If you are blessed with higher wind speed average consider our Mark II or III with heavier windings. Our PMA’s will reach cut in speeds and produce power in and low as 6 mph wind and we can demonstrate this. The below video features our dual PMA wired in series not the single PMA therefore the output would be roughly half or twice the RPM to achieve the RPM you are viewing in the video In my experience most customers do not care about an open voltage times shorted amps chart value calculated in 70 mile per hour winds. For these reasons we offer the open voltage multiplied by shortage amp style chart, The wattage output VS wind speed at battery bank environment, and monthly power output in KW hours per month to provide a comprehensive illustration of the capabilities of our products. Many power curves and charts are fiction i.e made, Mythical and comical. Open voltage multiplied by shorted amps do not give the customer a realistic perception of how much power a product will output. The two conditions are separate, open voltage measurements are not taken under a load while shorted amp readings are. This information is useful for some purposes but virtually useless for others. If you are interested we have charted the Cat 4 Mark IPMA in that format as well. Hurricane manufactures its own PMA’s no vendor is used, it is not imported, and is designed, manufactured and assembled in Roanoke Virginia USA. Since we make stock and assemble the product we have control over the warranty process. All products whether they are built by myself, a third party vendor, or simply imported will have issues. This is the way of the world and the is simply no way around it. People, nor material goods are free of imperfection. The issue becomes how a company deals with and customer service issues which arise. We are willing to go the extra mile. We will meet or exceed anyone’s warranty in the business. We have the parts in stock and if something goes wrong with you product we are not faced with the decision to take the “hit” and throw the product in the dumpster. Logically speaking, if we can build it we can repair it. Dual PMA shown performing under water Power output is limited to the power input of the old worn out drill but you get the point. The ability of to cool with an open design is very important due to the fact closed sealed PMA’s will lose power from the buildup of heat and eventually fail due to the stator inability to dissipate heat burning up windings. It is really a point of common sense. If you were in a hot metal box would you rather have it sealed with a cooling fin attached to the outside of your box or have a window open? The following is written with the intent of addressing wind applications but many of the principles apply to electromagnetic – mechanical transfer of energy in general. I apologize in advance for the length of the explanation but in the interest in the health of my jaw joint and phone bill, I will attempt here to lay out the basics as many of my new to the field. My customers want information and facts not puffery exaggerated, claims and “fantastic assertions”. How a Wind Generator works The science is what it is and we will tell you exactly why you should buy from Hurricane. The majority of what you have read while shopping for a wind generator PMA is fiction as I have eluded previously. We have inserted the following playlist so you may see the science behind the products if you are new to the field. Kinetic Energy transferred from the wind striking a surface, typically a set of blades is transferred to a generator. In the vast majority of all designs a magnetic rotor rotates around a stator a set of stationary coils, or the stator rotates around a stationary rotor. The force measured in torque eg. Ft/lbs, Newtons, Joules ect. that is transferred to the generator is changed in form from mechanical energy to electrical. Power input from a source has nothing to do with the generator or permanent magnet alternator but ultimately dictates the maximum power than may be output by a generator. This is why wattage rating without understanding input torque needed leads many to disappointment. Fast forward about 3 minutes in for the significant of the illustration The law of conservation of energy applies “ energy can neither be created nor destroyed but change form eg kinetic to mechanic, mechanical to electrical” ect. Simply stated it takes power to make power. To achieve maximum power from a wind generator the two elements which are of the essential are the amount of power or torque input from a source or blades set, and the efficiency of the generator. The circumference of the rotor area, number of blades are some of the variables which determine torque produced from a given rotor/blade set. The input torque eg. Maximum mechanical energy input is relative to the amount of electrical energy that can be extracted from generator. These same principle of torque input apply whether we are speaking of a wind generator, hydro, gas, diesel or any other power source which drive a permanent magnet alternator. In other words it takes power to make power Myth… the claw or zig zag design in a permanent magnet alternator is inferior? About Rotors Why the claw shape is superior…. The rotor has 7 poles sets distributed as “claws” around it’s circumference. One set of claws is thus a “north” pole and the other set is a “south” poles. The epoxy coated N 45 neo core magnet In Hurricane Rotors deeply saturates the stator. The iron originally used in the pole claw has been replaced utilizing higher efficiency shapes and forged steel a used in Hurricane permanent magnet alternators. The magnetic flux lines within the rotor are largely constrained to flow from one pole to the other through the claw structures at each end trapezoidal claw, folding around the internal magnetic structure and passing between the claws through a zig-zag shaped circumferential air gap. There is no reverse flux flow through the rotor shaft itself. The rotor shaft is magnetically entrained and acts as yet another part of the rotor Magnetic rotor. The shape of the zig-zag gap between the claw pieces, being air and much less permeable than the forged steel and directs the magnetic flux into a similar zig-zag shape. So as the rotor rotates there will be a position where this gap exactly bisects a stator segment and both the “north” and the “south” claws on either side of the gap will have an equal magnetic influence on it. As it continues to rotate more and more of the “north” or “south” claw will come adjacent to this particular stator coil, thus transferring the particular magnetic field polarity into it. This zig-zag “claw” design therefore prevents abrupt magnetic transitions from taking place in the stator segments as the rotor is turned. preventing abrupt transitions this elegant design thus largely eliminates any tendency to have a location, or a series of locations, where the magnetic path is more permeable and thus more attractive than adjacent locations. It is these variations in permeability around the circumference that are the cause of magnetic “cogging” in slotted magnet rotor designs. Of three companies rotor we examine which use this design two of three used magnet to wide for the field which is highly inefficient causing huge losses, heat buildup, e.g. eddy current resistive effects. In other words opposing poles entering the same field essentially fight against each other We have examined multiple “plate and grove designs” and I as well as many customers have found that some of the companies offering this type of design build PMA which have a terrible cogging effect and provide virtually no low end power . Faraday- Lenz Law Systems do not like change! The things that you should be concerned with when buying a generator for maximum efficiency are as follows. 1.Rotor design and strength……this is simple as strong as possible designed in a manner in which the shaft is not difficult to turn and is designed in a manner to promote cogging. Also there are poor designs on the market I have examine that has poles to wide for the fields thus making the PMA terribly inefficient. 2. The air gap between the rotor and stator must be exact. This cannot be done be hand and should be done with precision to the 1000th of an inch to maximize efficiency 3. Stators should be wound with a gauge of wire and winding connection that is appropriate for the particular application. E.g. high wind, wind. Battery bank voltage environment e.g. 12, 24, or 48 volt or the set point for the grid tie you are using. We use 400 degree wire in out stators which will withstand the test of time and extreme conditions. There is nothing magical about a hand wound stator other that the manufacturer could not afford to have enough wound to his specifications and made per the requirement he desired. Moreover by having the buying power to have our product wound professionally the wind is tighter allowing more copper to be wound into areas withing the stator which have deep flux saturation. 4. CRAFTSMANSHIP all connections must be made professionally, products such as lock tite used new parts forged with precision, A PMA is only as good as the person building it. If something does not fot precisely it is not good. Quality Control and balance of the rotating assembly not only effect performance they effect the longevity of a product. An out of balance product will wear the air gap between rotor and stator and guarantee a short bearing live. 5 Value. We pledge you will not find a better product for the money period. Hurricane Learning LAB: if you are interested in the science behind the products here it is. No pitch nothing fancy it is what it is. Finally I do not consider myself the ultimate authority on Physics if you have a PHD in your pocket and have feedback we would love to hear from you. If your permanent magnet alternator manufacturer does not understand the principles contained within this playlist, they will be inept whether their task be manufacturing or importing. Perhaps it’s time to consider a Hurricane. Froo www.froo.com | Froo Cross Sell, Free Cross Sell, Cross promote, eBay Marketing, eBay listing Apps, eBay Apps, eBay Application FREE! Sellers: Add a FREE map to your listings. FREE! Hurricane Wind Power Build News Magazine Best Off Grid 2016 Renewable Energy Product Supplier UP TO -50% DISCOUNTS TOP BRANDS Payment We accept payment by any of the following methods: PayPal Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner! Shipping We offer Fast shipping on all orders! Your order will be dispatched within 1-3 working day of receiving payment (Monday-Friday) and you should expect to receive it one or two days after dispatch (for orders sent RM 1st Class). In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement. Returns If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not. You can return a product for up to 14 days from the date you purchased it. Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt. Thank you for visiting our Ebay store! See our other items
Frequently Asked Questions About Hurricane Wind Power 24 Volt Permanent Magnet Alternator PMA Delco in My Website
www.amea-care.gr is the best online shopping platform where you can buy Hurricane Wind Power 24 Volt Permanent Magnet Alternator PMA Delco from renowned brand(s). www.amea-care.gr delivers the most unique and largest selection of products from across the world especially from the US, UK and India at best prices and the fastest delivery time.
What are the best-selling Hurricane Wind Power 24 Volt Permanent Magnet Alternator PMA Delco on www.amea-care.gr?
www.amea-care.gr helps you to shop online and delivers Fila to your doorstep. The best-selling Fila on www.amea-care.gr are: Fila Vf9240 Col 0700 Shiny Black Rectangle Eyeglasses Frames 55-14-140 Fila Womens Memory Foam Sneakers Pink Blue Gray White Size 9.5 FILA MB Mens Basketball Shoes Size 11 Egret Gray Blue Yellow Jamal Mashburn Fila Original Fitness Shoes Mens Sz 13 Blue White Red Low Top Sneakers Fila Doublewide Solid Wristbands FILA Axilus 2.5 Energized Purple Tie Dye Tennis Shoes – Womens S 9.5 MSRP – $115 Fila All Terrain Black Men’s Athletic Shoes – 1JM01275-016 Size 10.5 Women’s Fila Disruptor II Premium White/Navy/Red 5FM00002-125 FILA Men’s TERATACH 600 MID Size 10.5 White /Gardenia/ Gum Patent Leather FILA A-High Triple Black Faux Leather Shoes Men Sneakers Fila Forlani Outline Flag Womens White Motorsport Inspired Sneakers Shoes Fila Disruptor Ii Midnight Garden Womens Shoes Fila OakMont TR Trainers 1JM01747-704 Men’s Size 7 NEW without box Fila Men’s Mid-Cut A-High Athletic Sneakers 1CM00540-600 Red Size 13M Fila Grant Hill 2 Sneakers for Men – WhiteBlack -Size 45 FILA MB Mens Basketball Shoes Size 10 Beige Black Orange Blue Jamal Mashburn FILA MB Mens Athletic Basketball Shoes Size 11.5 Black Red Bred Jamal Mashburn Fila Men’s F13 PS Shoes Suede Gray Size 10 Fila Ray Tracer TR 2 Mid Shoes – NEW Mens Size 12 Black / Black – #44881-TOP Men’s T-Shirt-FILA Stacked Logos Retro Sporty Style-100% Cotton-Size S_M_L Fila Grant Hill 3 Woven Mens Shoes Fila Women’s Disruptor II Premium Athletic Sneakers Size 10 FILA BOOTS BLACK MENS ZIP CHASTIZER 1LM00116-001 Fila Volley Zone Pickleball Mens Black Sneakers Athletic Shoes 1PM00596-016 Fila Morales Men’s Size 11 Shoes Black Canvas Low Top Sneakers 1CM01544-013 Men FILA Renno Red Suede White Blue RETRO EDITION Running Lace Up Sneakers 10 Fila Ray TRACER mens Size 11 Athletic Shoes New Fila Disruptor II Animal Women’s Size 7.5 Athletic Fashion Shoes 5XM00806-992 Fila Fazal Basketball Shoes Size 10 M Fila Men’s Black Stackhouse Spaghetti Basketball Sneakers 1BM01871 Mens Fila Original Fitness Classic Retro Casual Athletic Shoes White Navy Red NEW FILA Motorsport Exalade 6 Women’s Black Athletic Shoes Sneakers Size 6.5 FILA Disruptor 2 Premium , Women’s 6, Chunky Leather Sneakers, 100 Triple White Fila Original Fitness Men’s Shoes Black-White 1FM01722-021 Fila Axilus Lace Up Youth Boys Blue Sneakers Casual Shoes 3TM00597-430 Fila Men’s A-High Shoes Sneakers 1CM00540-100 – White/White Fila Suspence Winspeed Athletic Running Shoes Grey Pink Size 7.5 New Size 6Y / Women’s 7.5 FILA F-13 Weather Tech Boots 3SH40121-060 CastleRock Fila Womens 5CM00772-125 White Casual Shoes Sneakers Size 11 Fila Men’s Disruptor II Premium Shoes White/Navy/Red 1FM00139-125 Fila Men’s Black Trazorus 2 Energized Sneaker Shoe Walking Athletic Gym NEW! Fila Impress LL Yellow Athletic Shoe Men 10 FILA Fila Stack 2 MSS23004109 White Blue Silver Fila All Terrain Black Men’s Athletic Shoes – 1SHW0262-002 – Size 11.5 FILA ORIGINAL FITNESS Shoes Women’s US 6.5 EU 37.5 Canary Yellow 5FM00631-732 FILA Womens Sneakers SORE 2 Running Training ATHLETIC Shoes SIZE 9.5 Grey Fila Mb Stitch Mens Shoes NIB – FILA – Women’s Sleek Marble Slide Sandals, Pink & White, 8 Men’s FILA A-Low Classic Casual Comfy Shoe / Triple White / 1CM00551 100 Fila black sneakers memory foam size 9 Men’s Fila Sneakers/Shoes High Top Black Size 12 Basketball Lace up/Hook & Loop Fila Renno X Dragon Ball Super Vegeta Sneakers Fila Heritage Tormo Platform Pink Women’s Shoes Size 7 Sample New Without Box Fila Disruptor II Wedge 5CM01842-014 Womens Black Lifestyle Sneakers Shoes Fila Vulc 13 Marble Mens Shoes Size 8.5 : White/Metallic Gold/White Fila Red Crimson Skyweave Men’s Sneaker, #1CM00356-600, Size 9 Fila Armada Mens Shoes FILA Women’s Disruptor II Premium Pale Banana Sneakers Fila Breakaway 10 Mens Shoes Fila Women’s Renno Sneakers Lemon/Knockout/ Pink Black 5CM01616-710 Size 7.5 M Fila Disruptor II Checker Womens Shoes Size 9 Black/White Checkered Men’s Fila, Chastizer Work Boot 1LM00984-001 Solid Black Leather Mesh Synthetic Fila Men’s Oakmont Tr [1JM01565-865] Sneaker Shoes, 11 M US Fila Oakmont TR Mid Men’s Shoes Ponderosa-Espresso-Black 1JM01276-362 FILA Sneakers Women’s 8 Purple Memory Foam Cool Max Athletic Running Shoes Fila Lombardi Mint Sneakers 10 Women Lace Up Low Top Running Shoes 5RM00366-421 FILA Blue/white Running Athletic Shoes Womens Size 9 1/2 Fila Edgewater 12 PB 1HM00872-467 Mens Blue Synthetic Casual Dress Boots Fila Disruptor II Wedge 5CM01842-013 Womens Black Lifestyle Sneakers Shoes Fila Sandenal Men’s – 1RM02203-117 Fila Sandenal Men’s Shoes Seedpearl-Oxford Tan-Black 1RM01646-201 FILA RAY TRACER TR 2 Sneakers DSMT/BTRR/LEMO -248 New Women’s Sz 5.5 Pink Fila Disruptor 2 Sneakers Premium Shoes Running Mens Fila Grant Hill 2 25th Anniversary Basketball Shoe / Black / 1BM01374 / NEW FILA Mens Size 6.5 Electrove 2 Chunky Sneaker Shoes Orange Black Street FILA Women’s Disruptor II Premium Silver Sneakers Fila Forlani Outline Flag Mens White Motorsport Inspired Sneakers Shoes Fila Windshift 15 Womens Shoes Fila Memory Stir Up 3 size 7 gray/mint women’s running shoes NEW 5RM02131-253 Men Fila Sneakers Navy Blue White Red Size 8 Fila Mens Superstride 4 1RM01889-001 Black Lace Up Sneaker Shoes Size 9.5 Fila Men’s Skele-Toes EZ-SLIDE Barefoot Summer Water Shoes Black Outdoor 8 Med Fila Faux Suede Hightop Sneakers Shoes Athletic Mens Size 9 Black FW00420-003 Fila Mens 1SC60526-030 Black Basketball Shoes Sneakers Size 12 Fila Armada Mens Shoes Fila 1CM01569-019 Fila Renno N Generation Men’s Size 10.5 Black Gray Orange Men’s FILA Renno Sneakers, Pre-Owned, 10 1/2, Minimal Wear, EUC Fila Stackhouse Spaghetti Men’s Shoes Black-Pinecone-Purple 1BM01269-972 Women’s FILA No Show Socks [1BM01873-125] NEW MEN’S FILA STACKHOUSE SPAGHETTI WHITE FILA NAVY FILA RED FM80 FILA~NWOB!!~BLACK LEATHER LACE-UP SLIP RESISTANT MEMORY FOAM SNEAKERS WOM: 11W Men’s Size 9 FILA Oakmont TR S/N 1JM01565-865 Fila Speedserve Energized Tennis Mens White Sneakers Athletic Shoes 1TM01778-10 [1BM00866-125] Mens Fila GRANT HILL 2 [1BM01788-014] Mens Fila STACKHOUSE SPAGHETTI Mens 8.5 – Fila Fast Trek Trail 1JM01662-055 Gray Synthetic Running Hiking Shoes Fila Mens Vulc 13 1SC60526-125 White Basketball Shoes Sneakers Size 8 Fila Corda Lace Up Mens Black Sneakers Casual Shoes 1TM01797-001 Mens FILA Teratach 600 Casual Athletic Work Shoe/ Black Red White / 1BM00872 014 Men’s Fila Original Fitness Casual Shoe 11-F16LT-150 New In Box Size 10.5 Mens Pullover Fleece Hoodie